Standard Output
+++ Running case: MATLAB-122
+++ working dir: /Users/jenkins/workspace/macOS-Intel-Basic/nightlylog
| boundary conditions for stressbalance model: spc set as zero
| no balancethickness.thickening_rate specified: values set as zero
| uploading input file and queuing script
| launching solution sequence on remote cluster
| Ice-sheet and Sea-level System Model (ISSM) version 4.24
| (GitHub: https://issmteam.github.io/ISSM-Documentation/ Documentation: https://github.com/ISSMteam/ISSM/)
| call computational core:
| write lock file:
| FemModel initialization elapsed time: 0.461395
| Total Core solution elapsed time: 6.1178
| Linear solver elapsed time: 4.41787 (72%)
| Total elapsed time: 0 hrs 0 min 6 sec
| SUCCESS difference: 1.8e-10 < 1e-09 test id: 122 test name: SquareShelfConstrainedTransHOEnth field: Vx1
| SUCCESS difference: 1.6e-10 < 1e-09 test id: 122 test name: SquareShelfConstrainedTransHOEnth field: Vy1
| SUCCESS difference: 2.4e-11 < 1e-09 test id: 122 test name: SquareShelfConstrainedTransHOEnth field: Vz1
| SUCCESS difference: 1.5e-10 < 1e-09 test id: 122 test name: SquareShelfConstrainedTransHOEnth field: Vel1
| SUCCESS difference: 1e-16 < 1e-09 test id: 122 test name: SquareShelfConstrainedTransHOEnth field: Pressure1
| SUCCESS difference: 6.7e-13 < 1e-09 test id: 122 test name: SquareShelfConstrainedTransHOEnth field: Bed1
| SUCCESS difference: 6.7e-13 < 1e-09 test id: 122 test name: SquareShelfConstrainedTransHOEnth field: Surface1
| SUCCESS difference: 6.7e-13 < 1e-09 test id: 122 test name: SquareShelfConstrainedTransHOEnth field: Thickness1
| SUCCESS difference: 2.1e-16 < 1e-09 test id: 122 test name: SquareShelfConstrainedTransHOEnth field: Temperature1
| SUCCESS difference: 1.2e-15 < 1e-09 test id: 122 test name: SquareShelfConstrainedTransHOEnth field: Enthalpy1
| SUCCESS difference: 0 < 1e-09 test id: 122 test name: SquareShelfConstrainedTransHOEnth field: Waterfraction1
| ERROR difference: 0.0022 > 1e-09 test id: 122 test name: SquareShelfConstrainedTransHOEnth field: Vx2
| ERROR difference: 0.0025 > 1e-09 test id: 122 test name: SquareShelfConstrainedTransHOEnth field: Vy2
| ERROR difference: 0.0016 > 1e-08 test id: 122 test name: SquareShelfConstrainedTransHOEnth field: Vz2
| ERROR difference: 0.0025 > 1e-09 test id: 122 test name: SquareShelfConstrainedTransHOEnth field: Vel2
| ERROR difference: 0.004 > 1e-09 test id: 122 test name: SquareShelfConstrainedTransHOEnth field: Pressure2
| ERROR difference: 8.8e-06 > 1e-09 test id: 122 test name: SquareShelfConstrainedTransHOEnth field: Bed2
| ERROR difference: 8.8e-06 > 1e-09 test id: 122 test name: SquareShelfConstrainedTransHOEnth field: Surface2
| ERROR difference: 8.8e-06 > 1e-09 test id: 122 test name: SquareShelfConstrainedTransHOEnth field: Thickness2
| ERROR difference: 4.4e-05 > 1e-09 test id: 122 test name: SquareShelfConstrainedTransHOEnth field: Temperature2
| ERROR difference: 0.00024 > 1e-09 test id: 122 test name: SquareShelfConstrainedTransHOEnth field: Enthalpy2
| ERROR difference: 0.00018 > 1e-09 test id: 122 test name: SquareShelfConstrainedTransHOEnth field: Waterfraction2
| ERROR difference: 0.0053 > 1e-09 test id: 122 test name: SquareShelfConstrainedTransHOEnth field: Vx3
| ERROR difference: 0.0054 > 1e-09 test id: 122 test name: SquareShelfConstrainedTransHOEnth field: Vy3
| ERROR difference: 0.003 > 1e-08 test id: 122 test name: SquareShelfConstrainedTransHOEnth field: Vz3
| ERROR difference: 0.0054 > 1e-09 test id: 122 test name: SquareShelfConstrainedTransHOEnth field: Vel3
| ERROR difference: 0.008 > 1e-09 test id: 122 test name: SquareShelfConstrainedTransHOEnth field: Pressure3
| ERROR difference: 2.7e-05 > 1e-09 test id: 122 test name: SquareShelfConstrainedTransHOEnth field: Bed3
| ERROR difference: 2.7e-05 > 1e-09 test id: 122 test name: SquareShelfConstrainedTransHOEnth field: Surface3
| ERROR difference: 2.7e-05 > 1e-09 test id: 122 test name: SquareShelfConstrainedTransHOEnth field: Thickness3
| ERROR difference: 0.00013 > 1e-09 test id: 122 test name: SquareShelfConstrainedTransHOEnth field: Temperature3
| ERROR difference: 0.0007 > 1e-09 test id: 122 test name: SquareShelfConstrainedTransHOEnth field: Enthalpy3
| ERROR difference: 0.0015 > 1e-09 test id: 122 test name: SquareShelfConstrainedTransHOEnth field: Waterfraction3
+++ exit code: 0